Limited Time SaleUS$23.20 cheaper than the new price!!
| Management number | 211143942 | Release Date | 2026/04/04 | List Price | US$15.46 | Model Number | 211143942 | ||
|---|---|---|---|---|---|---|---|---|---|
| Category | |||||||||
REXC-700 Temperature Controller Digital PID Temperature Controller SSR Solid State 220V Universal Input Relay Output SSR OutputEX-C700 temperature controller:Features:2. This series of products is based on the most advanced modern control theory, using microcomputer single-chip control3. Intelligent temperature control instrument with PID self-tuning (automatic optimization) function4. For oven use, purpose, oven, temperature control 5. Used in various IT industries to control and monitor process temperatureSpecifications:Size: 11 x 7.2 x 7.2cm1. Measurement error: 3 levels: 1%+1 word, 0.5%±1 word, 0.2%±1 word.Additional cold junction compensation error: within the range of 0~50, ±2, temperature coefficient 0.05%/2. Measuring digital display range: one 1999 ~ 9999, -199 ~ 9999 two kinds.3. Alarm range: freely set the full range.4. Relay output contact capacity: 3A/220V, resistive or specified.5. SCR trigger signal: 15/40 u S or rated 100mA, instantaneous IA (self-trigger).6. Output signal of solid state relay: 15± 3V/3 0mA.7. Working power supply: 220V ~ ± 10% 50HZ; power consumption: 4W.8. Working environment: 0~50, relative humidity 35%~85%RH, non-corrosive and no strong electromagnetic field radiation.Note:1. Check whether the gauge indexing number specification and power supply voltage are the same as the ordered gauge.2. Wire correctly according to the wiring diagram.3. For the input signal of the thermocouple, please use the compensation wire of the same material as the thermocouple wire.4. For the thermal resistance input signal, please use the same specification and low resistance wire, and the length of the three wires should be the same as possible.5. Pay special attention to the power input line and the sensor signal input line not to be confused and connected incorrectly, otherwise the entire instrument will burn out and be scrapped.Can't be repaired. The output terminals cannot be short-circuited by strong currents.6. The power line and signal line of the instrument should be separated from the high-current output line as much as possible to reduce the influence of electromagnetic radiation on the instrument.If it is unavoidable, please try to use shielded wire for the connection of the instrument.Simple problem repair:After connecting the corresponding power line, sensor line and output control line according to the meter specifications, the PV window of the meter will display the measured value after power-on and the SV window will display the set value, and at the same time it will enter the automatic temperature control state.1. If you think the indicator is abnormal, please check the sensor and wiring.2. The display of various functions and output indications on the instrument panel are normal, and when the instrument is out of control, please check whether the output control line is connected correctly, whether the external load is short-circuited, open circuit, or wrong wiring, etc. Check whether the copper foil of the output terminal and the output protection resistor are burnt.Package Included:Temperature controller*1 (Excluding thermocouple and sensor)Buckle*2Manual *1 EX-C100 temperature controller:Specifications:Model: REX-C100FK02-V * ANMeasurement accuracy: ± 0.5% FSCold end compensation tolerance: ± 2 (can be modified by software in 0 ~ 50).Resolution: 14 bitSampling cycle: 0.5 SecDimensions: 48x48x88 (mm) ± 0.2mmProcess value (PV), set value (SV)Output, alarm and autotune can be indicated by: LEDSelf-adjusting controlOutput: 3A 250V AC contact capacity (resistive loadOutput contact capacity: 250V AC 3A (resistive load)Setting value (SV): identical to the measuring range (PV).Proportional band (P): 0 ~ full range (ON / OFF control when set to 0).Integral Time (I): 0 ~ 3600 seconds (no integral action when set to 0).Derivative Time (D): 0 ~ 3600 seconds (no derivative action when set to 0).Heat reset proportional cycle: 1 ~ 100 secTemperature range: 0 to 400Insulation resistance:> 50M ohm V DC (500V DC)Insulation resistance: 1500V AC / minPower consumption: 10 VAService Environment: 0 ~ 50,No corrosive gas environment 30 ~ 85% RHK Thermocouple probe Cable1. Length: 1M / 2M2. Diameter: 5mm3. Temperature range: 0-6004. Internal insulation: fiberglass5. External shield: Insulated shield40A SSR1. Output current: 40A2. Input voltage: DC 3-32V3. Output voltage: 24-380V AC4. Output voltage range: standard typePackage Included:1 * EX-C100 Digital Temperature Controller PID (Include thermocouple NOT)1 English x User ManualElectronic : NoMeasure Type : KTheory : Temperature ControllerDisplay Type : DIGITALPower Type : ChargerModel Number : REX-C700 REX-C100Origin : Mainland ChinaMax Measuring Temperature : 120°C & AboveStyle : Standing StationIs Smart Device : NoUse : IndustrialDisplay Size : 1.9 Inches & UnderFeature 1 : REX-C700 Digital PID Temperature ControllerFeature 2 : REX-C700 REX-C100 Universal Input Relay OutputFeature 3 : 0 To 400°C K Type Input SSR OutputFeature 4 : K Type Input Relay OutputFeature 5 : For Automatic Packing Machine
| Color | REX-C700-Relay M AN |
|---|---|
| Brand Name | ZXWXUE |
| Manufacturer | ZXWXUE |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form